Oras dishwasher
Oras dishwasher shut-off with touchless operation, temperature display with hot water warning, flexible high swivel spout, aerator, and smart dishwasher valve. Easy-grip levers for hot and cold water. There are separate levers for adjusting the hot and cold water flow rates. Spout’s swing angle is 120 degrees by default (but can be restricted to 60 or 80 degrees). Take your hands inside the recognition range to activate the touchless function. Turning the ring between the oras diskmaskinsavstängning and the spout changes the water temperature for the touchless feature. The touchless feature is easily turned on and off. Pressing a switch with a signal light opens the dishwasher valve, which closes automatically after a certain amount of time. Oras dishwasher shut-off valve automatically closes after four or twelve hours (one push opens the valve for 4 hours, pushing for 5 seconds opens the valve for 12 hours). Electrical connection using a 230/5 V plug transformer. Litter filters are installed in the faucet.
The Smart Press Pad, control panel, and electronic valve make up the Oras electronic remote valve. Because the valve is remote-controlled, it is not necessary to install it right close to the control panel. There is no need to drill holes into the countertop to install the remote valve.
Benefits of the remote valve from Oras:
For all sink and oras dishwasher shut-off that have inlet pipes connectable to either hot or cold water.
There are two types of the remote valve:
The battery-operated (3V) 272100 model and the power-operated model.
The manufacturer has already attached the components. Only while changing the press pad or control unit are the components needed to be reconnected.
Since the valve is wireless, the countertop does not require any drilling. The valve’s open time is set at 4 hours. By pressing the Press pad for a longer (5s) amount of time, the Press pad will extend the opening hours duration to 12 hours. Please be aware that certain outdated manuals may still contain inaccurate information concerning the three-hour opening window. Advice on maintaining the press pad
Repairing the Oras remote valve push pad
Low battery: the red and green lights flash; as soon as feasible, replace the push pad battery (CR 2450 3V Lithium). When the battery is empty, just the red light is on, and the valve does not open.
Battery replacement for the push pad:
Turn the lid in the opposite direction to release the push pad. With a tiny flat-blade screwdriver, carefully remove the battery; make note of the proper location. Place a fresh CR 2450 3V Lithium battery in its place, then turn the press pad lid clockwise to reinstall it.
Troubleshooting the Oras remote valve control unit:
Low battery: the green light flashes and the red light begins to flicker; immediately replace the control unit’s battery (2 pcs of AA 1.5V). Change the control unit battery if the green light flashes first, followed by two flashes of the red light, and the valve does not open. Empty battery (AA 1.5V Lithium)
Changing the battery in the control unit:
Open the lid, take out the plug, then turn the screw. Utilizing a little screwdriver, remove the batteries. Put the lid on and swap the two AA 1.5V lithium batteries for fresh ones.